Festo Контроллер позиционирования CPX-CMAX User Manual
Page 234
5. Parameter
5−46
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Record setpoint value
PNU
PNU: 404
Index: 1 ... 64
Max index: 64
Class: Array
Data type: int32
Values
Unit depends on control mode: Position (index = 1) or force (index = 3)
Default: 0
Minimum: −1.000.000
Maximum: 1.000.000
Control mode position (RCB1.COM1 = 0):
Position setpoint value in unit position (index 1)
Control mode force (RCB1.COM1 = 1):
Force setpoint value in unit force (index 3)
o
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Record preselection value
PNU
PNU: 405
Index: 1 ... 64
Max index: 64
Class: Array
Data type: int32
Values
Unit depends on sequencing condition: Position, force, time (index = 1, 3, 9)
Default: 0
Minimum: −1.000.000
Maximum: 1.000.000
Contains the value at which sequencing occurs.
The meaning depends on the condition in RCB2 (PNU 402):
Switch. condition
Phys. unit
Index of the unit
2
Position
Position value
Index = 1
3
Force
Force value
Index = 3
4
Standstill
Time
Index = 9
5
Time
Time
Index = 9
11 Stroke
Position
Index = 1
12 MC
Time
Index = 9
13 Stroke after force
Position
Index = 1
14 Position at force
Position
Index = 1
o
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.