beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 234

background image

5. Parameter

5−46

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Record setpoint value

PNU

PNU: 404

Index: 1 ... 64

Max index: 64

Class: Array

Data type: int32

Values

Unit depends on control mode: Position (index = 1) or force (index = 3)

Default: 0

Minimum: −1.000.000

Maximum: 1.000.000

Control mode position (RCB1.COM1 = 0):

Position setpoint value in unit position (index 1)

Control mode force (RCB1.COM1 = 1):

Force setpoint value in unit force (index 3)

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Record preselection value

PNU

PNU: 405

Index: 1 ... 64

Max index: 64

Class: Array

Data type: int32

Values

Unit depends on sequencing condition: Position, force, time (index = 1, 3, 9)

Default: 0

Minimum: −1.000.000

Maximum: 1.000.000

Contains the value at which sequencing occurs.
The meaning depends on the condition in RCB2 (PNU 402):
Switch. condition

Phys. unit

Index of the unit

2

Position

Position value

Index = 1

3

Force

Force value

Index = 3

4

Standstill

Time

Index = 9

5

Time

Time

Index = 9

11 Stroke

Position

Index = 1

12 MC

Time

Index = 9

13 Stroke after force

Position

Index = 1

14 Position at force

Position

Index = 1

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.