Festo Контроллер позиционирования CPX-CMAX User Manual

Page 218

background image

5. Parameter

5−30

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

System password

PNU

PNU: 133

Index: 1 ... 2

Max index: 2

Class: Array

Data type: int32

Internal password for the FCT.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

ý

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

System time: count operating days .

PNU

PNU: 140

Index: 1

Max index: 2

Class: Struct

Data type: int32

Values

Days

Default: −

Minimum: −

Maximum: −

Number of operating days since new state, device data reset or a firmware download.

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

System time: milliseconds of the day .

PNU

PNU: 140

Index: 2

Max index: 2

Class: Struct

Data type: int32

Values

ms

Default: −

Minimum: −

Maximum: −

Number of milliseconds of the current operating day (PNU 140:01).
When switching on, the last value before switching off is loaded.

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

The PNU 140 does not contain data of a real−time clock.
The number of operating days is counted by the CMAX, saved
when switching off and re−loaded when switching on. 1 operĆ
ating day consists of:
24 * 60 * 60 * 1000 ms = 86.400.000 ms