4 description of the parameters, 1 overview of parameters, Description of the parameters – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 205: Overview of parameters
5. Parameter
5−17
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
5.4
Description of the parameters
5.4.1
Overview of parameters
The following overview (Tab. 5/14) sho ws the FHPP’s
parameters. The parameters are described in sections 5.4.2
to 5.4.16.
PNU
1)
Name (DE)
Properties
1)
PNU
IND
Max
(
)
Class
Type
Unit
RW
SH IB
NB UL
Device data, see section 5.4.2
100
1
1
Hardware version of
manufacturer
Var
int32
0
R
101
1
1
Firmware version of
manufacturer
Var
int32
0
R
102
1
1
FHPP version
Var
int32
0
R
103
X
30
Build version
Array
char
0
R
104
X
3
Software versions
Var
int32
0
R
105
1
1
Boot loader version
Var
int32
0
R
114
1
1
Controller serial number
Var
bitarray
0
R
116
X
33
FCT project identifier
Array
char
0
RW
UL
120
X
30
Manufacturer’s device name
Array
char
0
R
121
X
30
User’s device name
Array
char
0
RW
UL
122
X
30
Manufacturer name
Array
char
0
R
123
X
30
HTTP address of manufacturer Array
char
0
R
124
X
30
Festo order number
Array
char
0
R
130
X
30
Password
Array
char
0
W
UL
133
X
2
Secret system password
Var
int32
0
RW
140
1
2
System time: Qty. operating
days
Struct int32
0
R
140
2
2
System time: millisec. of the
day
Struct int32
0
R
180
X
30
Name of X−axis
Array
char
0
RW
UL
181
X
30
Name of Y−axis
Array
char
0
RW
UL
1)
see Tab. 5/15