Dell POWEREDGE M1000E User Manual
Page 968

936
Fabric OS Command Reference
53-1001764-02
switchShow
2
To display blade information and port names:
switch:admin>
switchshow -slot 5 -portname
FC Router: OFF
Allow XISL Use: OFF
LS Attributes:[FID: 128, Base Switch: No, Default Switch: Yes, Address Mode 0]
Slot Blade Type ID Status
-------------------------------------------------
5 COREBLADE 52 ENABLED
Index Slot Port Name
===================================================
384 5 0 MyName_portname0
385 5 1 ------
386 5 2 ------
To display the domain ID offset on a switch in interop mode 2:
switch:admin>
switchshow
switchName: WT_Pulsar_77
switchType: 32.0
switchState: Online
switchMode: McDATA Fabric
switchRole: Principal
DomainIDOffset: 0x20
switchDomain: 2
switchId: fffc25
switchWwn: 10:00:00:05:1e:35:71:8b
zoning: OFF
switchBeacon: OFF
FC Router: OFF
FC Router BB Fabric ID: 1
[output truncated]
To display media type information (relevant output excerpts only):
•
The following example shows switchshow output for the ge0 and ge1 ports on a Brocade 7800.
The ge0 port is a copper port (default). The ge1 has an SFP installed (copper or optical):
[...]
ge0 cu 1G No_Sync FCIP Copper
ge1 id 1G No_Light FCIP
ge2 -- 1G No_Module FCIP
ge3 -- 1G No_Module FCIP
ge4 id 1G Online FCIP
ge5 -- 1G No_Module FCIP
[...]
•
This example shows switchshow output for a Brocade 5100. Port 31 has an SFP installed.
Nothing is installed on Port 30.
[...]
31 31 421f00 id N4 In_Sync FC Disabled
32 32 422000 -- N8 No_Module FC Disabled
[...]