Ficoncupshow – Dell POWEREDGE M1000E User Manual
Page 350
318
Fabric OS Command Reference
53-1001764-02
ficonCupShow
2
ficonCupShow
Displays FICON-CUP parameters for a switch.
Synopsis
ficoncupshow fmsmode
ficoncupshow modereg [bitname]
ficoncupshow MIHPTO
ficoncupshow LP
Description
Use this command to display FICON-CUP (Control Unit Port) parameters for a switch.
Note
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details
Operands
This command has the following operands:
fmsmode
Display the FICON Management Server (FMS) mode for the switch.
modereg
Display the FICON-CUP mode register. If no operand is specified, all mode
register bit settings are displayed. If a mode register bit name is specified,
then only the value of that bit is displayed. A value of 1 indicates that a given
mode register bit is set, and 0 indicates that it is not set.
The following operand is optional:
bitname
Displays the specified mode register bit as either set (1) or not set (0). Valid
values for bitname are:
POSC
Programmed offline state control
UAM
User alert mode
ASM
Active=saved mode
DCAM
Director clock alert mode
ACP
Alternate control prohibited
HCP
Host control prohibited
MIHPTO
Displays the FICON-CUP missing interrupt handler primary timeout (MIHPTO)
value in seconds.
LP
Displays the logical paths on the switch. For each entry, the command
displays the port identifier (PID), the LPAR identifier (CHID), reporting state
(operational or reset (=nonoperational)), and path (current or primary).
Examples
To display the FMS mode for the switch:
switch:user>
ficoncupshow fmsmode
fmsmode for the switch: Enabled