Dell POWEREDGE M1000E User Manual
Page 773
Fabric OS Command Reference
741
53-1001764-02
portPerfShow
2
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
===============================================================================
0 210.1m 840.5m 210.1m 0 0 0 0 0 0 0 0 0 0 0 0
32 33 34 35 36 37 38 39 Total
==============================================
0 0 0 0 0 0 0 0 2.5g
(output stopped)
To display performance on a single port with at a 5 second interval:
switch:user>
portperfshow 0 -t 5
0 Total
=================
630.4m 630.4m
0 Total
=================
630.3m 630.3m
(output stopped)
To display transmitter throughput for a single port at a 5 second interval:
switch:user>
portperfshow 0 -tx -t 5
0
========
210.1m
0
========
210.1m
(output stopped)
To display receiver throughput for a single port at a 5 second interval:
switch:user>
portperfshow 0 -rx -t 5
0
========
420.3m
0
========
420.2m
(output stopped)
To display port performance on a chassis for range of ports at an interval of 5 seconds:
switch:user>
portperfshow 12/0-12/6 -t 5
0 1 2 3 4 5 6 Total
===============================================================
slot 12: 840.6m 0 0 0 0 0 630.4m 1.4g
0 1 2 3 4 5 6 Total
===============================================================
slot 12: 840.6m 0 0 0 0 0 630.4m 1.4g
0 1 2 3 4 5 6 Total
===============================================================
slot 12: 840.6m 0 0 0 0 0 630.4m 1.4g
(output stopped)
See Also
portStatsShow