beautypg.com

Dell POWEREDGE M1000E User Manual

Page 781

background image

Fabric OS Command Reference

749

53-1001764-02

portShow

2

To display the state of a VE_Port on a chassis with an FX8-24 blade:

switch:admin>

portshow 7/12

portIndex: 140

portName:

portHealth: No Fabric Watch License

Authentication: None

portDisableReason: None

portCFlags: 0x1

portFlags: 0x490b PRESENT ACTIVE VIRTUAL E_PORT G_PORT U_PORT

LOGICAL_ONLINE LOGIN LED

portType: 12.0

portState: 1 Online

Protocol: FC

portPhys: 255 N/A portScn: 16 E_Port

port generation number: 1048

state transition count: 26

portId: 018c00

portIfId: 43720806

portWwn: 20:8c:00:05:1e:7a:7a:00

portWwn of device(s) connected:

Distance: normal

switch:admin>

To display port status for a GbE port on a Brocade 7800:

switch:admin>

portshow ge2

Eth Mac Address: 00.05.1e.54.b1.17

Port State: 1 Online

Port Phys: 6 In_Sync

Port Flags: 0x4003 PRESENT ACTIVE LED

Port Speed: 1G

To view xlate domains, you must issue the command on a Brocade 7500/7500E or a chassis with
an FR4-18i blade. Note that the Front Domain ID is what is shown:

switch:admin>

portshow 8/4

portName:

portHealth: No Fabric Watch License

Authentication: None

EX_Port Mode: Enabled

Fabric ID: 20

Front Phantom: State: OK

Cur Dom ID: 160 WWN: 50:00:51:e3:60:ee:0e:14

Pr Switch Info: Dom ID: 5

WWN: 10:00:00:05:1e:34:02:04

Fabric params: R_A_TOV: 10000 E_D_TOV: 2000 PID fmt: core

Authentication Type: None

Hash Algorithm: N/A

DH Group: N/A

Edge fabric's primary wwn: N/A

Edge fabric's version stamp: N/A

portDisableReason: None