beautypg.com

Fwfrucfg – Dell POWEREDGE M1000E User Manual

Page 401

background image

Fabric OS Command Reference

369

53-1001764-02

fwFruCfg

2

fwFruCfg

Displays or modifies FRU state alert configuration.

Synopsis

fwfrucfg [--show]

Description

Use this command to configure field-replaceable unit (FRU) states and actions. Based on these
configuration settings, Fabric Watch generates actions when a FRU state changes. When used
without operand, this command interactively prompts for user input. To configure email alerts, use
fwMailCfg. This command is not applicable to platforms that do not support FRUs.

Notes

This command requires a Fabric Watch license.

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability"
for details.

Operands

This command has the following operand:

--

show

Displays the current FRU configuration setting. This operand is optional; if
omitted, the configuration prompt displays.

Examples

To change the FRU state alert configuration:

switch:admin>

fwfrucfg

The current FRU configuration:

Alarm State Alarm Action

-----------------------------------------------

Slot 0 1

Power Supply 0 0

Fan 0 0

WWN 0 0

Note that the value 0 for a parameter means that

it is NOT used in the calculation

Configurable Alarm States are:

Absent-1, Inserted-2, On-4, Off-8, Faulty-16

Configurable Alarm Actions are:

Errlog-1, E-mail-16

Slot Alarm State: (0..31) [0]

3

Slot Alarm Action: (0..17) [1]

Power Supply Alarm State: (0..31) [0]

Power Supply Alarm Action: (0..17) [0]

Fan Alarm State: (0..31) [0]

Fan Alarm Action: (0..17) [0]

WWN Alarm State: (0..31) [0]

WWN Alarm Action: (0..17) [0]

Fru configuration successfully changed

See Also

fwHelp, fwMailCfg