Fabric OS Command Reference
369
53-1001764-02
fwFruCfg
2
fwFruCfg
Displays or modifies FRU state alert configuration.
Synopsis
fwfrucfg [--show]
Description
Use this command to configure field-replaceable unit (FRU) states and actions. Based on these
configuration settings, Fabric Watch generates actions when a FRU state changes. When used
without operand, this command interactively prompts for user input. To configure email alerts, use
fwMailCfg. This command is not applicable to platforms that do not support FRUs.
Notes
This command requires a Fabric Watch license.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands
This command has the following operand:
--
show
Displays the current FRU configuration setting. This operand is optional; if
omitted, the configuration prompt displays.
Examples
To change the FRU state alert configuration:
switch:admin>
fwfrucfg
The current FRU configuration:
Alarm State Alarm Action
-----------------------------------------------
Slot 0 1
Power Supply 0 0
Fan 0 0
WWN 0 0
Note that the value 0 for a parameter means that
it is NOT used in the calculation
Configurable Alarm States are:
Absent-1, Inserted-2, On-4, Off-8, Faulty-16
Configurable Alarm Actions are:
Errlog-1, E-mail-16
Slot Alarm State: (0..31) [0]
3
Slot Alarm Action: (0..17) [1]
Power Supply Alarm State: (0..31) [0]
Power Supply Alarm Action: (0..17) [0]
Fan Alarm State: (0..31) [0]
Fan Alarm Action: (0..17) [0]
WWN Alarm State: (0..31) [0]
WWN Alarm Action: (0..17) [0]
Fru configuration successfully changed
See Also