beautypg.com

Dell POWEREDGE M1000E User Manual

Page 806

background image

774

Fabric OS Command Reference

53-1001764-02

portShow

2

Examples

To display iSCSI Port WWN and sessions:

switch:admin>

portshow iscsi 2/ge0

GE Port 2/ge0

Port WWN Sessions

-----------------------------------

50:06:06:9e:40:09:a2:00 0

To display the connection parameter information for all FCIP tunnels on the switch and to show the
current DiffServ markings being used for data connection as well as control connection (The
following example displays high-water marks in bold for the data and control TCP connections of
Tunnel 0):

switch:admin>

portshow fciptunnel -all -params

Port: ge0

-------------------------------------------

Tunnel ID 0

Tunnel Description "This is a test Description of this tunnel"

Remote IP Addr 192.168.10.2

Local IP Addr 192.168.44.9

Remote WWN Not Configured

Local WWN 10:00:00:05:1e:38:84:65

Compression off

Fastwrite off

Tape Pipelining off

Committed Rate 900000 Kbps (0.900000 Gbps)

SACK on

Min Retransmit Time 100

Keepalive Timeout 10

Max Retransmissions 8

VC QoS Mapping off

DSCP Marking (Control): 0, DSCP Marking (Data): 0

VLAN Tagging Not Configured

TCP Byte Streaming on

Status : Inactive

Connected Count: 0

Port: ge1

-------------------------------------------

Tunnel ID 0

Tunnel Description "This is a test Description of this tunnel"

Remote IP Addr 192.168.10.10

Local IP Addr 192.168.10.2

Remote WWN Not Configured

Local WWN 10:00:00:05:1e:39:37:5f

Compression off

Fastwrite off

Tape Pipelining off

Committed Rate 900000 Kbps (0.900000 Gbps)

SACK on

Min Retransmit Time 100

Keepalive Timeout 10

Max Retransmissions 8

VC QoS Mapping off

DSCP Marking (Control): 0, DSCP Marking (Data): 0

VLAN Tagging Not Configured

TCP Byte Streaming on

Status : Active

Connected Count: 3