Dell POWEREDGE M1000E User Manual
Page 806
774
Fabric OS Command Reference
53-1001764-02
portShow
2
Examples
To display iSCSI Port WWN and sessions:
switch:admin>
portshow iscsi 2/ge0
GE Port 2/ge0
Port WWN Sessions
-----------------------------------
50:06:06:9e:40:09:a2:00 0
To display the connection parameter information for all FCIP tunnels on the switch and to show the
current DiffServ markings being used for data connection as well as control connection (The
following example displays high-water marks in bold for the data and control TCP connections of
Tunnel 0):
switch:admin>
portshow fciptunnel -all -params
Port: ge0
-------------------------------------------
Tunnel ID 0
Tunnel Description "This is a test Description of this tunnel"
Remote IP Addr 192.168.10.2
Local IP Addr 192.168.44.9
Remote WWN Not Configured
Local WWN 10:00:00:05:1e:38:84:65
Compression off
Fastwrite off
Tape Pipelining off
Committed Rate 900000 Kbps (0.900000 Gbps)
SACK on
Min Retransmit Time 100
Keepalive Timeout 10
Max Retransmissions 8
VC QoS Mapping off
DSCP Marking (Control): 0, DSCP Marking (Data): 0
VLAN Tagging Not Configured
TCP Byte Streaming on
Status : Inactive
Connected Count: 0
Port: ge1
-------------------------------------------
Tunnel ID 0
Tunnel Description "This is a test Description of this tunnel"
Remote IP Addr 192.168.10.10
Local IP Addr 192.168.10.2
Remote WWN Not Configured
Local WWN 10:00:00:05:1e:39:37:5f
Compression off
Fastwrite off
Tape Pipelining off
Committed Rate 900000 Kbps (0.900000 Gbps)
SACK on
Min Retransmit Time 100
Keepalive Timeout 10
Max Retransmissions 8
VC QoS Mapping off
DSCP Marking (Control): 0, DSCP Marking (Data): 0
VLAN Tagging Not Configured
TCP Byte Streaming on
Status : Active
Connected Count: 3
Uptime 23 minutes, 53 seconds