Dell POWEREDGE M1000E User Manual
Page 716
684
Fabric OS Command Reference
53-1001764-02
portCfgShow
2
To display an FCIP Tunnel on a Brocade FX8-24 with and without IPSec information:
switch:admin>
portcfgshow fciptunnel 7/12 -ipsec
-------------------------------------------
Tunnel ID: 7/12
Tunnel Description:
Compression: Off
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Enabled
IPSec Key: '01234567890123456789012345678901'
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:7a:7a:00
Flags: 0x00000000
FICON: Off
switch:admin>
portcfgshow fciptunnel 7/12
-------------------------------------------
Tunnel ID: 7/12
Tunnel Description:
Compression: Off
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:7a:7a:00
Flags: 0x00000000
FICON: Off
To display inband management interfaces configured on the Brocade 7500:
switch:admin>
portcfgshow inbandmgmt ge1
Inband management: Enabled
Port: ge1
CP Interface IP Address NetMask MTU
----------------------------------------------------------
0 192.168.255.1 255.255.255.252 1500
Port: ge1
GE Interface IP Address NetMask MTU
----------------------------------------------------------
0 192.168.255.2 255.255.255.252 1500
See Also
portCfg, portCfgCreditRecovery, portCfgEport, portCfgGport, portCfgLongDistance,
portCfgLPort, portCfgNPIVPort, portCfgSpeed, portCfgTrunkPort, portSwapDisable,
portSwapShow, switchShow