Iscsiportcfg – Dell POWEREDGE M1000E User Manual
Page 492
460
Fabric OS Command Reference
53-1001764-02
iscsiPortCfg
2
iscsiPortCfg
Displays or modifies iSCSI port parameters.
Synopsis
iscsiportcfg --clearstats slot/geport
iscsiportcfg --default slot/geport
iscsiportcfg --show slot/geport [-v]
iscsiportcfg --modify slot/geport options
Description
Use this command to display or modify the iSCSI port parameters.
The default iSCSI port settings are as follows:
TABLE 21
Default iSCSI port settings
Note
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands
This command has the following operands:
--
modify
Modifies the port parameters on the specified port. Valid options are:
-e value
Specifies the error recovery level; values are 0, 1, or 2.
-c value
Specifies the TCP of connections; values are 1 or 2.
-d value
Enables or disables data digest support; specify 0 to disable or 1 to enable.
-a value
Enables or disables header digest support; specify 0 to disable or 1 to
enable.
-i value
Enables or disables immediate data support; specify 0 to disable or 1 to
enable.
-f value
Specifies the first burst length value; values include 512, 1024, 2048, 4096,
8192, 16384, and 32768.
--
clearstats
Clears port-level iSCSI statistics on the specified port.
--
default
Resets the port to the default values. See the "Description" section for the list
of default values.
Setting
Default
Error recovery level
0
Connections per session
1
Connections per session
Disabled
Header digest support
Disabled
Immediate data support
No
First burst length value