beautypg.com

Dell POWEREDGE M1000E User Manual

Page 326

background image

294

Fabric OS Command Reference

53-1001764-02

fcrPathTest

2

Notes

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability"
for details.

This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms.

The switch must be offline for this test to run.

Operands

This command has the following operands:

--

slot slot

Specifies the slot number on which the diagnostic operates. The default is 0
and operates on fixed-port-count products.

-unit number

Specifies the FC Router FPGA to test. By default, all FC Router FPGAs in the
specified slot are tested. Valid number values include:

0

FC Router FPGA 0

1

FC Router FPGA 1

2

All FC Router FPGAs

-path mode

Specifies the loopback point for the test. By default, fcrPathTest uses the
Central ASIC loopback. Valid mode values include:

1

Central ASIC loopback

2

FC Router FPGA Serdes loopback

3

FC Router FPGA internal loopback

-nframes count

Specifies the number of frames to send. The test progresses until the
specified number of frames are transmitted on each port. The default value is
10.

Examples

To test slot 2 with FC Router FPGA Serdes loopback sending 10 frames:

switch:admin>

fcrpathtest

--

slot 2 -path 2 -nframes 10

Running fcrpathtest ..............

Test Complete: fcrpathtest Pass 10 of 10

Duration 0 hr, 0 min & 18 sec (0:0:18:942).

passed.

Diagnostics

When a failure is detected, the test may report one or more of the following:

DIAG-DATA

The payload received by the specified port did not match the transmitted
payload. A cable, media, or ASIC failure is the probable cause. Check for a
faulty SFP. Replace the SFP if necessary.

DIAG-ERRSTAT

One of the ASIC internal counters detected a frame statistics error in the
received frame. A cable, media, or ASIC failure is the probable cause. Check
for a faulty SFP. Replace the SFP if necessary.

DIAG-INIT

The port failed to synchronize in the loopback mode requested. A cable,
media, or ASIC failure is the probable cause. Check for a faulty SFP. Replace
the SFP if necessary.

DIAG-PORTDIED

The specified port was in loopback mode and then lost sync. A cable, media,
or ASIC failure is the probable cause. Check for a faulty SFP. Replace the SFP
if necessary.