beautypg.com

Portstatsshow – Dell POWEREDGE M1000E User Manual

Page 821

background image

Fabric OS Command Reference

789

53-1001764-02

portStatsShow

2

portStatsShow

Displays port hardware statistics.

Synopsis

portstatsshow [slot/]port

portstatsshow -i [index1[-index2][...] [-f]]

portstatsshow -slot [slot1[-slot2][...]

portstatsshow ge [slot/]geport

portstatsshow ip [slot/]geport [ip_address]

portstatsshow fcip [slot/]geport [tunnel_number]

portstatsshow -h

Description

Use this command to display port hardware statistics counters. Some counters are platform- or
port-specific and display only on those platforms and ports. All statistics have a maximum 32-bit
value of 4,294,967,295.

You can display statistics for a single port identified by its port number or by its port index. Port
ranges are supported with index numbers and by specifying a slot or a slot range. Use switchShow
for a listing of valid ports, slots, and port index numbers.

Specifying multiple ports with the index (-i) or slot (-s) option is supported only if PortSwap is
disabled. They are not supported on GbE ports and configured F_Port trunks. Use the -i option
without a port index to display the portSwap status, or alternately use portSwapShow.

The command output may include the following fields (Tx indicates frames transmitted by the port;
Rx indicates frames received by the port).

stat_wtx

The number of 4-byte words transmitted.

stat_wrx

The number of 4-byte words received.

stat_ftx

The number of frames transmitted.

stat_frx

The number of frames received.

stat_c2_frx

The number of class 2 frames received.

stat_c3_frx

The number of class 3 frames received.

stat_lc_rx

The number of link control frames received.

stat_mc_rx

The number of multicast frames received.

stat_mc_to

The number of multicast timeouts.

stat_mc_tx

The number of multicast frames transmitted.

tim_rdy_pri

The number of times that sending R_RDY or VC_RDY primitive signals was a
higher priority than sending frames, due to diminishing credit reserves in the
transmitter at the other end of the fiber. This parameter is sampled at
intervals of 1.8 µs (microseconds), and the counter is incremented by 1 if the
condition is true.