Fabric OS Command Reference

629

53-1001764-02

portCfg

2

-

Create or modify a tunnel with Byte Streaming enabled or disabled.

portcfg fastwrite - Configure the FC port for FC FastWrite.

portcfg ficon - Manage FICON emulation in an FCIP tunnel.

Operands

This command supports the following operands:

slot

For bladed systems only, specifies the slot number of the port to be
configured, followed by a slash (/).

ge_port

Specifies the number of the port to be configured, relative to its slot for
bladed systems. The GbE ports on the Brocade 7500/7500E, and FR4-18i
are numbered ge0 - ge1. Use the switchShow command for a list of valid
ports.

arp

Optionally adds entries to the address resolution protocol (ARP) table or
deletes entries from ARP table. Can also be used to flush the entire table. The
syntax for portcfg arp is as follows:

portcfg arp [slot/][ge]port options arguments

Valid options and arguments for arp include:

add ipaddr macaddr

Adds a static ARP entry to the ARP table. Specify an IP address and a MAC
address for each entry. Use portShow arp with the -lmac option to get the
MAC address.

delete ipaddr

Deletes a static ARP entry from the ARP table. Only the IP address must be
specified to delete the entry.

flush

Flushes the ARP table. Only dynamic entries can be flushed, static entries
cannot be cleared.

fciptunnel

Creates, modifies, or deletes a Fibre Channel over IP (FCIP) tunnel. You can
configure up to a maximum of eight FCIP tunnels per GbE port. The syntax for
portCfg fciptunnel is as follows:

portcfg fciptunnel [slot/][ge]port options arguments [optional_arguments]

The following options and arguments are supported with fciptunnel:

create tunnel_id dest_ipaddr src_ipaddr comm_rate

Creates an FCIP tunnel. You must specify a tunnel ID, destination and source
IP address, and committed rate when creating an FCIP tunnel. Other
configuration parameters are optional, and can be added later.

tunnel_id

Specifies the FCIP tunnel on the GbE port. Valid values are 0-7.

dest_ipaddr

Specifies the IP address for the remote end of the FCIP tunnel.

src_ipaddr

Specifies the IP address for the local end of the FCIP tunnel.

comm_rate

Specifies the committed traffic rate on the FCIP tunnel in Kbps. Valid
range is 1,544 to 1,000,000. Specify 0 for an uncommitted tunnel.
Uncommitted tunnels compete for bandwidth. Changing comm_rate is
potentially disruptive.