Dell POWEREDGE M1000E User Manual
Page 708
676
Fabric OS Command Reference
53-1001764-02
portCfgShow
2
QOS E_Port
Displays ON when Quality of Service (QoS) is enabled on the E_Port (or
EX_Port) when QoS is enabled in an FCR deployment scenario. Displays (..) or
OFF when QoS is disabled. By default, QoS is enabled if sufficient buffers are
available. Displays AE when QoS is configured as Auto Enabled. In the AE
state, QoS is enabled based on the availability of buffers.
Use islShow to determine the current status of QoS (on or off) in the AE state.
This value is set by the portCfgQos command.
EX_port.
Displays ON when the port is configured as an EX_Port. Otherwise displays (..)
or OFF. This value is set by the portCfgExPort command.
Mirror Port
Displays ON when Mirror Port is enabled on the port. Displays (..) or OFF when
Mirror Port is disabled. This value is set by the portCfg mirrorport command.
FC Fastwrite
Displays ON when FC FastWrite is enabled on the port or (..) or OFF when
disabled. FastWrite is disabled by default. This value is set by the portCfg
fastwrite command.
Rate Limit
Displays ON when ingress rate limit is set on the port or (..) or OFF when the
ingress rate limiting feature is disabled. This value is set by the portCfgQos
--
setratelimit command. The default value is OFF.
Credit Recovery
Displays ON when Credit Recovery is enabled on the port. Displays (..) or OFF
when the feature is disabled. This value is set by the portCfgCreditRecovery
command. The credit recovery feature is enabled by default, but only ports
configured as long distance ports can utilize this feature.
Port Auto Disable
Displays On when the Auto Disable feature is enabled on a port. Displays (..)
or OFF when the feature is disabled. This feature causes ports to become
disabled when they encounter an event that would cause them to reinitialize.
This feature is enabled by the portCfgAutoDisable command. The feature is
disabled by default.
F_Port Buffers
Displays the number of configured F_Port buffers. Displays (..) or OFF if no
buffers are configured. The buffer value is set by the portCfgfPortbuffers
command.
NPIV PP Limit
Displays the maximum number of allowed logins for the port. Displays the
default of 126 or the configured maximum. This parameter is set with the
portCfgNPIVPort --setloginlimit command.
CSCTL mode
Currently not supported.
You can identify a single port to be displayed by its port number or by its port index number. Port
ranges are supported with index numbers or by specifying a slot or a slot range. Use switchShow for
a listing of valid ports, slots, and port index numbers. When used without operands, this command
displays all persistently disabled ports on the switch.
Specifying multiple ports with the index (-i) or slot (-s) option is supported only if PortSwap is
disabled. They are not supported on GbE ports and configured F_Port trunks. Use the -i option
without a port index argument to display the portSwap status, or alternately use portSwapShow.
Notes
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
The Fabric OS port configuration commands are not supported on FCoE ports.