Page 778
746
Fabric OS Command Reference
53-1001764-02
portShow
2
Protocol
Protocol used by the port: FC or FCoE.
portPhys
The port's physical state:
No_Card
No interface card present.
No_Module
No module (GBIC or other) present.
No_Light
Module is not receiving light.
Mod_Inv
Incompatible vendor or module speed mismatch.
No_Sync
Receiving light but out of sync.
In_Sync
Receiving light and in sync.
Laser_Flt
Module is signaling a laser fault.
Port_Flt
Port marked faulty.
Diag_Flt
Port failed diagnostics.
Lock_Ref
Locking to the reference signal.
portScn
The port’s last State Change Notification.
port generation number
The port’s generation number for the last offline state change.
portId
The port’s 24-bit port ID.
portIfId
The user port’s interface ID.
portWwn
The port’s world wide name.
portWwn of devices(s) connected
The World Wide Port Names of connected devices.
Distance
The port's long-distance level. In the case of LD mode, the user configured
distance and actual distance also are displayed. See portCfgLongDistance for
information on long distance levels.
Port part of other AD
Yes or No.
portSpeed
The port's fixed speed (1, 2, 4, or 8 Gbps) or negotiated speed (N1 Gbps, N2
Gbps, N4 Gbps, N8 Gbps or AN).
LE domain
The LE domain ID.
FC FastWrite
The status of FC FastWrite (ON or OFF).
If the port is configured as an EX_Port, the following additional port information is displayed:
EX_Port Mode
The port is configured as an EX_Port.
Fabric ID
The fabric ID assigned to this EX_Port; this is the fabric ID of the edge fabric
attached to this EX_Port.
Front Phantom
Information on the front phantom domain presented by this EX_Port. Includes
the preferred (if not active) or actual (if active) domain ID for the front domain
and the WWN of the front domain.
Pr Switch Info
Information on the principal switch of the edge fabric attached to this