Portcfglosstov – Dell POWEREDGE M1000E User Manual
Page 686
654
Fabric OS Command Reference
53-1001764-02
portCfgLossTov
2
portCfgLossTov
Enables or disables de-bouncing of signal loss for front end ports.
Synopsis
portcfglosstov [slot]/port mode
Description
Use this command to enable or disable the de-bouncing of loss of signal for 100 ms for front end
ports. Use portCfgShow to display the current setting.
If executed without operands, the command prints the usage.
Notes
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
On a chassis, this command must be executed on the active CP.
Operands
This command has the following operands:
slot
For bladed systems only, specifies the slot number of the port to be
configured, followed by a slash (/).
port
Specifies the port to be configured, relative to its slot for bladed systems. Use
switchShow to list valid ports.
mode
Specify 1 to enable the configuration. Specify 0 to disable the configuration.
Examples
To enable the configuration on port 1/5 and to display the configuration:
switch:admin>
portcfglosstov 1/5 1
switch:admin>
portcfgshow 1/5
Area Number:
5
Speed Level: AUTO(HW)
Fill Word: 0(Idle-Idle)
AL_PA Offset 13: OFF
Trunk Port ON
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
Locked E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
LOS TOV enable
ON
NPIV capability ON
QOS E_Port AE
Port Auto Disable: OFF
Rate Limit OFF
EX Port OFF
Credit Recovery ON
F_Port Buffers OFF
NPIV PP Limit: 126
CSCTL mode: OFF