Dell POWEREDGE M1000E User Manual
Page 709
Fabric OS Command Reference
677
53-1001764-02
portCfgShow
2
Operands
This command supports the following operands:
slot
For bladed systems only, specifies the slot number of the port to be
configured, followed by a slash (/).
port
Specifies the number of the port to be displayed, relative to its slot for bladed
systems. Use switchShow for a listing of valid port numbers.
-i index1[-index2]
Specifies a port or a range of ports identified by port index numbers. You can
specify multiple index ranges separated by a space, for example, -i 33-38
40-60.
-f
Ignores nonexisting ports. This operand is valid only with the -i option.
-slot slot1[-slot2]
Specifies a slot or a range of slots. You can specify multiple slot ranges
separated by a space, for example, -s 1-3 5-7.
ge_port
Specifies the number of the GbE Port to be displayed. The GbE ports are
numbered ge0 - ge9 on the Brocade FX8-24 blade and ge0 - ge5 on the
Brocade 7800 switch. The 10GbE ports on the Brocade FX8-24 blade are
numbered xge0 and xge1. The GbE ports on the Brocade 7500/7500E, and
FR4-18i are numbered ge0 and ge1. Use the switchShow command for a list
of valid ports.
Use portCfgshow with a GbE port or with one of the following optional arguments to display specific
FCIP-related parameters.
Displays supported only on the Brocade 7800 /FX8-24 and on the Brocade 7500/7500E/FR4-18i
platforms
The following operands are optional; if omitted, all of the configuration settings are displayed on
the 7500/7500E/FR4-18i platforms, along with the FCIP tunnels. When issued on the Brocade
7800/FX8-24, tunnels and parameters not applicable to these platforms are not displayed. Use the
portShow command to display FCIP tunnel and circuit parameters on the Brocade 7800/FX8-24.
ipif
Displays the IP interface for both ports of the tunnel. IPv6 addresses are
supported on the Brocade 7500/7500E/FR4-18i platforms, and on the
Brocade 7800/FX8-24 platforms with Fabric OS v6.4.0.
iproute
Displays the IP route on the specified GbE port. IPv6 addresses are
supported. IPv6 addresses are supported on the Brocade
7500/7500E/FR4-18i platforms, and on the Brocade 7800/FX8-24
platforms with Fabric OS v6.4.0.
arp
Displays the address resolution protocol (ARP) table.
vlantag
Displays the VLAN tagging configuration. For each entry, the output displays
the IP interface address, the destination IP address, the VLAN ID, and the L2
CoS priority. This display includes permanent entries only. Permanent entries
are configured at the IP interface level with the portCfg vlantag command. To
view VLAN tagged tunnels and circuits along with permanent entries, use the
portShow vlantag command.
fciptunnel
Displays FCIP tunnels and related parameters. Valid arguments for fciptunnel
include:
all
Displays information for all FCIP tunnels.