Dell POWEREDGE M1000E User Manual
Page 779
Fabric OS Command Reference
747
53-1001764-02
portShow
2
BB XLate
Information on the xlate (translate) phantom domain presented at this port.
Includes the preferred (if not active) or actual (if active) domain ID for the
xlate phantom domain and the WWN of the xlate phantom domain. The xlate
phantom domain connected at this port is in the same fabric as the router
and represents the edge fabric connected to the EX_Port.
Authentication Type
Displays NONE or DH-CHAP. DH-CHAP is the only authentication type
supported on EX_Ports.
DH Group
Displays DH group [0-4] if DH-CHAP authentication is used. Otherwise
displays N/A.
Hash Algorithm
Displays hash type (MD5 or SHA-1) if DH-CHAP authentication is used.
Otherwise, displays N/A.
Edge fabric’s primary WWN
If the EX_Port is connected to an edge switch with FCS policy enforcement,
the WWN of the primary FCS is displayed when the edge fabric is secure and
the primary FCS is online. Otherwise, displays “No Primary”.
Edge fabric’s version stamp
If the EX_PORT is connected to an edge switch with FCS policy enforcement,
the version of the security database is displayed. Otherwise displays N/A.
The portShow command displays FCoE ports with "Protocol: FCoE" and "portSpeed: 10Gbps". Only
a subset of information is displayed. Refer to the example section for an illustration. Use fcoe
--
cfgshow and fcoe --loginshow to display FCoE-specific configuration details.
Following the general information, the command displays three columns of counters. The first
column shows interrupt statistics:
Interrupts
Total number of interrupts.
Unknown
Interrupts that are not counted elsewhere.
Lli
Low-level interface (physical state, primitive sequences).
Proc_rqrd
Frames delivered for embedded N_Port processing.
Timed_out
Frames that have timed out.
Rx_flushed
Frames requiring translation.
Tx_unavail
Frames returned from an unavailable transmitter.
Free_buffer
Free buffer available interrupts.
Overrun
Buffer overrun interrupts.
Suspended
Transmission suspended interrupts.
Parity_err
Central memory parity errors.
2_parity_err
Secondary transmission parity errors.
CMI_bus_err
Control message interface errors.
The second column displays link error status block counters.
The third column shows the number of F_RJTs and F_BSYs generated. For L_Ports, the third
column also displays the number of loop initialization protocols (LIPs) received, number of LIPs
transmitted, and the last LIP received.