704
Fabric OS Command Reference
53-1001764-02
portErrShow
2
portErrShow
Displays a port error summary.
Synopsis
porterrshow
Description
Use this command to display an error summary for all ports. Counts are reported on frames
transmitted by the port (Tx) or on frames received by the port (Rx). The display contains one output
line per port. Numeric values exceeding 999 are displayed in units of thousands (k), or millions (m)
if indicated.
Values for the following parameters are displayed:
frames tx
Number of frames transmitted (Tx).
frames rx
Number of frames received (Rx).
enc in
Number of encoding errors inside frames received (Rx).
crc err
Number of frames with CRC errors received (Rx).
crc g_eof
Number of frames with CRC errors with good EOF received (Rx).
too shrt
Number of frames shorter than minimum received (Rx).
too long
Number of frames longer than maximum received (Rx).
bad eof
Number of frames with bad end-of-frame delimiters received (Rx).
enc out
Number of encoding error outside of frames received (Rx).
disc c3
Number of Class 3 frames discarded (Rx). This counter includes the sum of
the following class 3 discard counters reported by the portStatsShow
command: er_rx_c3_timeout, er_tx_c2_timeout, er_c2_dest_unreach, and
er_other_disc. Refer to portStatsShow help for a description of these
counters.
link fail
Number of link failures (LF1 or LF2 states) received (Rx).
loss sync
Number of times synchronization was lost (Rx).
loss sig
Number of times a loss of signal was received (increments whenever an SFP
is removed) (Rx).
frjt
Number of transmitted frames rejected with F_RJT (Tx).
fbsy
Number of transmitted frames busied with F_BSY (Tx).
Note
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command
Availability" for details.
This command is not supported on FCoE ports.
Operands
none