678
Fabric OS Command Reference
53-1001764-02
portCfgShow
2
ve_port
Displays information for the specified FCIP tunnel on the Brocade
7800/FX8-24 (only). To display the tunnel, specify the VE_Port number
associated with the tunnel configured on one of the GbE ports. VE_Ports
are numbered 16-23 on the Brocade 7800 and 12-31 on the Brocade
FX8-24 blade.
tunnel_id
Displays information for the specified FCIP tunnel on the Brocade
7500/7500E/FR4-18i only. valid tunnel IDs are 0 to 7.
-ipsec
On the 7500/7500E/FR4-18i, this option displays IKE and IPSec policy
information on IPSec-enabled tunnels. On the Brocade 7800/FX8-24,
this option displays whether IPSec is enabled or disabled. If enabled, the
key is displayed. This operand is optional.
-qosmap
Displays the VC to QoS mapping. This operand is optional and valid only
on the 7500/7500E/FR4-18i.
Displays supported only on the Brocade 7500/7500E/FR4-18i platforms
When executed on the Brocade 7800/FX8-24, the following commands are not blocked, but return
no relevant information.
mode
Displays the mode of the specified GbE port as FCIP or not configured.
inbandmgmt
Displays any inband management interfaces configured on the Brocade
7500 for a specified GbE port. This command is not supported on the
FR4-18i blade.
Examples
To display the port configuration settings for a single port on a Brocade DCX-4S:
switch:admin>
portcfgshow 1/3
Area Number: 3
Speed Level: AUTO(HW)
Fill Word: 0(Idle-Idle)
AL_PA Offset 13: OFF
Trunk Port ON
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
Locked E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
LOS TOV enable OFF
NPIV capability ON
QOS E_Port AE
Port Auto Disable: OFF
Rate Limit OFF
EX Port OFF
Mirror Port OFF
Credit Recovery ON
F_Port Buffers OFF
NPIV Max Login Limit: 126
CSCTL mode: OFF