beautypg.com

Psshow – Dell POWEREDGE M1000E User Manual

Page 852

background image

820

Fabric OS Command Reference

53-1001764-02

psShow

2

psShow

Displays power supply status.

Synopsis

psshow

Description

Use this command to display the current status of the switch power supplies.

The status of each supply is displayed as:

OK

Power supply functioning correctly.

absent

Power supply not present.

unknown

Unknown power supply unit installed.

predicting failure

Power supply is present but predicting failure.

faulty

Power supply present but faulty (no power cable, power switch turned off,
fuse blown, or other internal error).

For certain switch models, the OEM serial ID data displays after each power supply status line.

Note

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command
Availability
" for details.

Operands

none

Examples

To view the status of the power supplies:

switch:admin>

psshow

Power Supply #1 is OK

DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000088

Power Supply #2 is faulty

DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000162

Power Supply #3 is OK

DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000120

Power Supply #4 is absent

See Also