beautypg.com

Perfttmon – Dell POWEREDGE M1000E User Manual

Page 626

background image

594

Fabric OS Command Reference

53-1001764-02

perfTTmon

2

perfTTmon

Installs the Top Talker monitor in the specified mode.

Synopsis

perfttmon

Port Mode (F_Port):

perfttmon --add egress | ingress [slot/]port

perfttmon --show [slot/]port [number_of_flows] [wwn| pid]

perfttmon --delete [slot/]port

Fabric Mode:

perfttmon --add fabricmode

perfttmon --show dom domain id [number_of_flows] [wwn| pid]

perfttmon --delete fabricmode

Description

Use this command to install the Top Talker monitor. The TopTalker feature provides real-time
information about the top 'n' bandwidth consuming flows from a set of a large number of flows
passing through a specific point in the network (after initial stabilization).

Top Talkers can display between 1 and 32 flows depending on hardware platform. The maximum
flows displayed are as follows:

32

For the Brocade 300, 5100, 5300, 8000 (FC Ports only) and FC8-xx port
blades.

16

For the Brocade 4100, 4900, 5000, 7600, and FC4-xx port blades.

4

For the Brocade 7500.

Top Talker supports two modes, Port Mode and Fabric Mode:

In Port Mode, Top Talker is installed on an F_Port to measure the traffic originating from the
F_Port and flowing to different destinations. The output displays the data in a sorted order
based on the data rate of each flow.

In Fabric Mode, Top Talker measures the top "n" bandwidth using flows on a given switch. Top
Talker installs only on E_Ports and measures the data rate of all the possible flows in the
fabric. Flow is a pair of communicating FC addresses (SID and DID). Top Talkers in Fabric Mode
and EE monitors are mutually exclusive. EE monitors must be removed from all switches before
enabling fabric mode.

Notes

This command requires an Advanced Performance Monitor license.

Top Talkers are incompatible with Frame Redirection, and therefore this feature is not supported on
the Brocade Encryption switch for encrypted data traffic.

Top Talkers are not supported on embedded platforms.

Top Talkers are not supported on VE_Ports, EX_Ports, VEX_Ports, FCoE ports or ports configured as
mirror ports.

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability"
for details.