882

Fabric OS Command Reference

53-1001764-02

snmpConfig

2

--

show, --set, and --default support the following arguments:

snmpv1

Selects SNMPv1-related configuration parameters. These parameters include
the community string, trap recipient IP address, and trap severity level
associated with each trap recipient IP address. When "0" is configured as a
trap port, traps can be received at the default port 162.

snmpv3

Selects SNMPv3-related configuration parameters. These parameters include
the user name, authentication protocol and password, the privacy protocol
and password, the SNMPv3 trap recipient’s IP address, its associated user
index and trap severity level. When "0" is configured as a trap port, traps can
be received at the default port 162.

In Fabric OS 6.3.0 and later, the --set snmpv3 command supports an
interactive option to enable or disable informs by setting the parameter
“SNMP Informs Enabled” to true or false. If informs are enabled, all trap
destinations receive inform requests. If informs are disabled, all trap
destinations receive trap requests. When informs are enabled, the engine ID
must be set to correspond to the management engine IP address (see
example). Informs are by default disabled. IPv6 Informs are currently not
supported.

accessControl

Selects access-control-related parameters. These parameters include the
access host subnet area and access permission (read-write).

mibCapability

Selects configuration parameters related to the SNMP agent’s MIBs and trap
capability parameters. These parameters include MIBs and traps supported
by the SNMP agent.

systemGroup

Selects configuration parameters related to the system group. These
parameters include sysDescr, sysLocation, sysContact, and authentication
failure trap.

secLevel

Sets the SNMP security level.

SNMPv1 Configuration Parameters
The agent supports six communities and their associated trap recipients and trap recipient severity
levels. The first three communities are for read-write (rw) access and the last three are for
read-only (ro) access. The default value for the trap recipient of each community is 0.0.0.0. The
length of the community string should be in the range of 2 to 16 characters. The default values for
the community strings are:

Community 1: Secret Code

Community 2: OrigEquipMfr

Community 3: private

Community 4: public

Community 5: common

Community 6: FibreChannel

When an FCS policy s enabled, community strings can be changed on the primary FCS switch only,
and only the primary FCS switch propagates changes across the fabric.