beautypg.com

Step 3: turn off the auto save function, Step 4: do an autotest, Step 5: look at the results – Fluke Networks CertiFiber Pro Users Manual User Manual

Page 56

background image

Versiv Cabling Certification Product Family
Technical Reference Handbook

34

Step 3: Turn Off the Auto Save Function

For this tutorial, you will manually save the test results.
3-1 On the home screen, tap the Next ID panel.

3-2 On the CHANGE ID screen, tap the Auto Save control to make

it show Off.

3-3 Tap DONE.

Step 4: Do an Autotest

4-1 Attach the channel adapters to the main and remote testers.

4-2 Turn on both testers, then connect a twisted pair cable

between the adapters.

4-3 Tap TEST on the main tester or press  on the main or

remote tester.

Step 5: Look at the Results

The tester shows the Autotest results in three formats (Figure 11):

WIRE MAP: Shows the connections between the ends of the
cable.

PERFORMANCE: Shows the overall result for each test. Use
this screen to quickly see which test failed.

Plot and tabular results screens: Tap a test on the
PERFORMANCE screen to see a table or plot of the results.

If you set HDTDR/HDTDX to All Autotests, you can see the
analyzers’ results on the DIAGNOSTIC tab.