How to add a result to a saved fiber results – Fluke Networks CertiFiber Pro Users Manual User Manual
Page 324

Versiv Cabling Certification Product Family
Technical Reference Handbook
302
FaultMap results from an OptiFiber Pro OTDR module.
Real Time Trace results from End 2 and End 1 from an
OptiFiber Pro OTDR module.
Loss/length results from a CertiFiber Pro OLTS module.
Power meter results from a CertiFiber Pro OLTS
module.
Tap the ID/Date control to sort the results by cable ID or by date.
When you sort by ID, the results show in ascending order. When
you sort by date, the latest result is at the top of the list.
How to Add a Result to a Saved Fiber Results
You can save the results from different fiber tests in one cable ID.
For example, you can save the bi-directional OTDR results and
FiberInspector results together in one ID.
When you add results, these settings used to get the results must
agree with the settings in the saved result:
Test limit
Fiber categories (singlemode/multimode, core size, category)
Index of refraction (makes a warning you can override)
If the settings do not agree, the tester shows a warning.
To add results, select an End setting and a test as necessary, make
sure the Next ID is correct, then do the test and save the result.
To add results for a different End setting
1
On the home screen, tap the Next ID panel.
2
On the CHANGE ID screen, tap the End 1/End 2 control to
make it show the correct end.