beautypg.com

Optifiber pro otdr module specifications (cont.) – Fluke Networks CertiFiber Pro Users Manual User Manual

Page 407

background image

Chapter 17: Specifications

OptiFiber Pro OTDR Module Specifications

385

OptiFiber Pro OTDR Module Specifications (cont.)

Multimode

Singlemode

Test time per wavelength

Auto

5 seconds (typical)

10 seconds (typical)

Quick Test

2 seconds (typical)

5 seconds (typical)

Best Resolution

2 to 180 seconds

5 to 180 seconds

FaultMap

2 seconds typical
180 seconds maximum

10 seconds typical
180 seconds maximum

DataCenter
OTDR

1 second typical at 850 nm
7 seconds maximum

20 seconds typical
40 seconds maximum

Manual

3, 5, 10, 20, 40, 60, 90, 120,
180 seconds

3, 5, 10, 20, 40, 60, 90, 120,
180 seconds

Laser
classification

Class I CDRH
Complies to EN 60825-2

Class I CDRH
Complies to EN 60825-2

Real Time Trace
refresh rate

2 updates per second
typical

2 updates per second
typical