Fluke Networks CertiFiber Pro Users Manual User Manual
Page 360

Versiv Cabling Certification Product Family
Technical Reference Handbook
338
For example, here is an installation with eight fibers:
Two rooms: rooms 17 and 18
Two fiber cables in each room: cables 1 and 2
Two fibers in each cable: fibers A and B
You can make this ID set for the installation:
First ID: ROOM 17 FIBER 1A
Last ID: ROOM 18 FIBER 2B
These IDs make this set of eight IDs:
ROOM 17 FIBER 1A
ROOM 17 FIBER 1B
ROOM 17 FIBER 2A
ROOM 17 FIBER 2B
ROOM 18 FIBER 1A
ROOM 18 FIBER 1B
ROOM 18 FIBER 2A
ROOM 18 FIBER 2B
Each project can have up to 5000 IDs. If an ID set does not have a
Last ID, the tester counts the set as one ID. An ID can have a
maximum of 60 characters.
To make an ID set
Note
When you make an ID set, the tester saves it in the
project shown on the home screen.
1
On the home screen, tap the PROJECT panel.
2
On the PROJECT screen, tap NEW ID SET.
3
On the CABLE ID SETUP screen, tap the First ID panel, then
use the keyboard to enter the first ID for the set.