Chapter 17: Specifications

Summary of Performance Specifications

377

Directivity

1 MHz to 300 MHz: 
27 - 7log(f/100), 
30 dB maximum
300 MHz to 600 MHz:
23.7 dB
600 MHz to
1,000 MHz: 
30.7 - 9 log(f/100)
(applicable when IL >
3 dB)

1 MHz to 300 MHz: 
25 - 7 log(f/100), 30 dB maximum
300 MHz to 600 MHz: 21.7 dB
600 MHz to 1,000 MHz: 
27.7 - 9 log(f/100)
(applicable when IL > 3 dB)

Source
Match

20 dB (applicable when IL > 3dB)

Return loss
of
Termination

1 MHz to 250 MHz: 
20 - 15log(f/100), 
25 dB maximum
250 MHz to 600 MHz:
14 dB
600 MHz to
1,000 MHz: 
21 - 9 log(f/100)
(applicable when IL >
3 dB)

1 MHz to 250 MHz: 
18 - 15 log(f/100), 25 dB maximum
250 MHz to 600 MHz: 12 dB
600 MHz to 1,000 MHz: 
19 - 9 log(f/100)
(applicable when IL > 3 dB)

Table 20. Level V Accuracy Performance Parameters

per IEC Guidelines (continued)

Parameter

Baseline Field Tester

Field Tester with

Level V

Permanent Link

Adapter

Field Tester with

Level V Channel

Adapter