beautypg.com

Visual fault locator, Di-1000 video probe, Visual fault locator di-1000 video probe – Fluke Networks CertiFiber Pro Users Manual User Manual

Page 410

background image

Versiv Cabling Certification Product Family
Technical Reference Handbook

388

Visual Fault Locator

DI-1000 Video Probe

On/off control

Mechanical switch and a button on the
touchscreen

Output power (into SM fiber
with SC/UPC connector)

316 µw (-5 dBm) peak power 1.0 mW
(< 0 dBm)

Operating wavelength

650 nm nominal

Spectral width (RMS)

3 nm

Output modes

Continuous wave and pulse mode (2 Hz to 3 Hz)

Connector adapter

2.5 mm universal

Laser safety

Class II CDRH over operating temperature
range
Complies to EN 60825-2

Magnification

200X with OptiFiber Pro display

Light source

Blue LED

Connection to OptiFiber Pro
tester

USB type A plug

Power source

Power supplied by the main Versiv unit

Field-of-view (FOV)

Horizontal: 425 µm
Vertical: 320 µm

Minimum detectable
particle size

<0.5 µm

Dimensions

Approximately 6.75 in long x 1.5 in diameter
(1175 mm x 35 mm) without adapter tip

Weight

7 oz. (198 g)

Temperature range

Operating: 32 °F to 122 °F (0 °C to +50 °C)
Storage: -4 °F to +158 °F (-20 °C to +70 °C)

Certifications

(when used with the main Versiv unit)