beautypg.com

Fluke Networks CertiFiber Pro Users Manual User Manual

Page 398

background image

Versiv Cabling Certification Product Family
Technical Reference Handbook

376

Residual
NEXT

90 – 20 log(f/100)
(measured to 85 dB
maximum)

85 - 20 log(f/100)
(measured to
85 dB maximum)

1-600 MHz: 
82.3 - 20 log(f/100)
600-1,000 MHz:
97.9 - 40 log(f/100)
(measured to
85 dB maximum)

Residual
FEXT

80 - 20 log(f/100)
(measured to 85 dB
maximum)

75 - 20 log(f/100)
(measured to
85 dB maximum)

60 - 15 log(f/100)
(measured to
85 dB maximum)

Output
Signal
Balance

1-600 MHz: 
40 - 20 log(f/100)
600-1,000 MHz:
24.4 dB
(measured to 60 dB
maximum)

1 - 600 MHz: 37 - 20 log(f/100)
600 - 1,000 MHz: 21.4 dB
(measured to 60 dB maximum)

Common
Mode
Rejection

40 - 20 log(f/100) 
(measured to 60 dB
maximum)

37 - 20 log(f/100)
(measured to 60 dB maximum)

Tracking

 0.5 dB (applicable when IL > 3 dB)

Table 20. Level V Accuracy Performance Parameters

per IEC Guidelines (continued)

Parameter

Baseline Field Tester

Field Tester with

Level V

Permanent Link

Adapter

Field Tester with

Level V Channel

Adapter