Fluke Networks CertiFiber Pro Users Manual User Manual
Page 398

Versiv Cabling Certification Product Family
Technical Reference Handbook
376
Residual
NEXT
90 – 20 log(f/100)
(measured to 85 dB
maximum)
85 - 20 log(f/100)
(measured to
85 dB maximum)
1-600 MHz:
82.3 - 20 log(f/100)
600-1,000 MHz:
97.9 - 40 log(f/100)
(measured to
85 dB maximum)
Residual
FEXT
80 - 20 log(f/100)
(measured to 85 dB
maximum)
75 - 20 log(f/100)
(measured to
85 dB maximum)
60 - 15 log(f/100)
(measured to
85 dB maximum)
Output
Signal
Balance
1-600 MHz:
40 - 20 log(f/100)
600-1,000 MHz:
24.4 dB
(measured to 60 dB
maximum)
1 - 600 MHz: 37 - 20 log(f/100)
600 - 1,000 MHz: 21.4 dB
(measured to 60 dB maximum)
Common
Mode
Rejection
40 - 20 log(f/100)
(measured to 60 dB
maximum)
37 - 20 log(f/100)
(measured to 60 dB maximum)
Tracking
0.5 dB (applicable when IL > 3 dB)
Table 20. Level V Accuracy Performance Parameters
per IEC Guidelines (continued)
Parameter
Baseline Field Tester
Field Tester with
Level V
Permanent Link
Adapter
Field Tester with
Level V Channel
Adapter