Technical Reference Handbook

90

selected test limit to calculate the LIMIT for each pair. The
VALUE is in a red box if it exceeds the LIMIT.

Note

The tester does the resistance unbalanced test
only if the test is required by the selected test limit
and the wire map test passed.

Frequency-Domain Results

Frequency-domain results are the measurements that change
with frequency, such as insertion loss and crosstalk.

How to Save Frequency-Domain Results as a Plot or a Table

If Store Plot Data is on when you do a test, the saved results show
as plots. If Store Plot Data is Off, the tester does not save plot data
for frequency-domain tests or for the HDTDR/HDTDX analyzers.
You can see the plots before you save the test and exit the results
screen.Figures 38 and 39 show examples of the two types of
screens. Also see “Store Plot Data” on page 72.

See Figure 38 on page 91:

The location where the tester made the measurements. To
switch between results for the main and remote, tap REMOTE
or MAIN (

).

The results are for the wire pair or pairs shown. To see the results
for a different pair or pairs, tap a tab on the right side of the
screen (

).

WORST MARGIN is the measurement that is nearest to the limit
line or exceeds the limit by the largest amount. WORST VALUE is
the worst measurement.

The measured value.

The limit specified by the selected test limit.