390

Internal Memory for Test Results

Typical capacity for the internal memory depends on the type of
tests you save:

Twisted pair tests: Approximately 12,700 Cat 6A Autotest
results, with plot data included.

Loss/length fiber tests: Approximately 30,000 fiber test results

OTDR tests: Approximately 2000 OTDR tests on fiber links
with an average length of 2 km, and up to 5000 tests for
lengths less than 2 km.

The capacity available for test results also depends on the space
used by the software and custom test limits in the tester.

The number of test records you can save decreases if you save
more tests in each record, or if you save tests that use more
memory. For example, twisted pair results saved with plot data
use more memory than results without plot data.

USB Flash Drive

You can upload test results to a USB flash drive to make more
internal memory available.

Note

The tester reads only USB drives that use the FAT
format.

Serial Interfaces

USB host interface with a type A USB port

USB interface with a Micro-AB USB port

RJ45 Connector

For functions available in future software releases.