Chapter 5: How to Diagnose Copper Test Failures
How to Use the Measurement Cursor on the HDTDR and HDTDX Plot
145
The green measurement bar goes from the start point to the end
point of your measurement.
To start another measurement, tap UNMARK. If UNMARK does