Chapter 7: How to Certify Fiber Cabling
Loss/Length Settings for Limits that Calculate a Loss Limit
171
Loss/Length Settings for Limits that Calculate
a Loss Limit
Some test limits do not specify a limit for loss measurements. They
specify maximum values of loss per kilometer of fiber and for the
connectors and splices in the link. Then, the tester uses the
measured length of the link, the number of connectors in the
link, and the number of splices in the link to calculate a loss limit
for that link.
When you select such a limit, you must enter the number of
connectors and splices that are in the link. To enter these values,
tap Reference Method or No. of Connections/Splices on the TEST
SETUP screen. See No. of Connections/Splices in Table 8 on page
174.