Db rules for tia channel test limits, Db rules for iso permanent link test limits, Es 4 – Fluke Networks CertiFiber Pro Users Manual User Manual
Page 142

Versiv Cabling Certification Product Family
Technical Reference Handbook
120
Table 4. dB Rules for TIA Channel Test Limits
Measurement
Cat 5e
Cat 6
Cat 6A
Return Loss
1
3 dB
3 dB
3 dB
NEXT
2
4 dB
4 dB
4 dB
PS NEXT
2
4 dB
4 dB
4 dB
ACR-F
3
70 dB
1. If insertion loss is less than 3 dB, Return Loss measurements are ignored.
2. If insertion loss is less than 4 dB, these measurements are ignored.
3. If FEXT is less than 70 dB, ACR-F measurements are ignored.
Table 5. dB Rules for ISO Permanent Link Test Limits
Measurement
Class D
Class E
Class E
A
Class F
Class F
A
Return Loss
1
3 dB
3 dB
3 dB
3 dB
3 dB
NEXT
2
4 dB
4 dB
4 dB
4 dB
4 dB
PS NEXT
2
4 dB
4 dB
4 dB
4 dB
4 dB
ACR-N
2
4 dB
4 dB
4 dB
4 dB
4 dB
PS ACR-N
2
4 dB
4 dB
4 dB
4 dB
4 dB
ACR-F
3
70 dB
70 dB
70 dB
ACR-F
4
65 dB
65 dB
65 dB
PS ACR-F
5
70 dB
70 dB
70 dB
PS ACR-F
6
62 dB
62 dB
62 dB
1. If insertion loss is less than 3 dB, Return Loss measurements are ignored.
2. If insertion loss is less than 4 dB, these measurements are ignored.
3. If FEXT is less than 70 dB, ACR-F measurements are ignored.
4. If the calculation of the FEXT limit value at a frequency is more than 65 dB, then the
limit at that frequency is 65 dB.
5. If PSFEXT is less than 70 dB, PS ACR-F measurements are ignored.
6. If the calculation of the PSFEXT limit value at a frequency is more than 62 dB, then
the limit at that frequency is 62 dB.