Versiv Cabling Certification Product Family
Technical Reference Handbook

126

Turn off the AC wire map test if the PoE device supplies power
on pairs 4,5 and 7,8. In those devices, the inputs and outputs
are fully isolated on those pairs. To do tests through those
devices, use a PoE test limit such as POE 2-Pair Cat 6 Perm.
Link
. The PoE limits are in the Application group on the TEST
LIMIT
screen.

How to Do an Autotest Through a PoE Device

1

Turn on the AC Wire Map test.

2

Make sure that the other settings shown on the home screen
are correct.

3

Connect to the cabling as shown in Figure 61 for a permanent
link or Figure 62 for a channel

4

Make sure that the PoE device is turned off.

5

Do an Autotest as described on page 75.

Notes

When you turn on the AC wire map test:

The Autotest takes more time.

The tester does not do some tests, such the
resistance test and the shield test.

The Autotest does not stop if there is a wire map
fault.

The tester does not do a continuity test on the
shield.