3 sflow counter interval, 4 sflow counter enable – CANOGA PERKINS CanogaOS Command Reference User Manual
Page 849
![background image](/manuals/651410/849/background.png)
CanogaOS Command Line Reference
Revision 1.02
Proprietary & Confidential Canoga Pertkins Metro Ethernet Switches
Page 849 of 855
two unique combinations can be allowed to add. Use the no parameter with this command to delete collector.
Examples
This example shows how to add a collector with IP address 10.0.0.254 and UDP port 3000.
Switch (config)# sflow collector 10.0.0.254 3000
Related Commands
45.3 sflow counter interval
Use this command to configure sFlow polling-interval for counter sample.
Command Syntax
sflow counter interval <1-2000>
no
sflow counter interval
sflow: Sampled flow
counter: Set sFlow interface counter
interval: Set interface counter interval
<1-2000>: Interval value in second
Command Mode
Global configuration mode
Usage
Use this command to set sFlow polling-interval for counter sample. Use the no parameter with this command
to set a default value. Default interval value is 20 seconds.
Examples
This example shows how to set sFlow polling-interval to 10 second
Switch (config)# sflow counter interval 10
Related Commands
45.4 sflow counter enable
Use this command to enable or
disable counter sampling on individual port
.
Command Syntax
(no|)
sflow counter
sflow: Set sFlow params
counter: sFlow interface counter
enable: Enable service