5 erps ring mode – CANOGA PERKINS CanogaOS Command Reference User Manual
Page 169
CanogaOS Command Line Reference
Revision 1.02
Proprietary & Confidential Canoga Pertkins Metro Ethernet Switches
Page 169 of 855
Only one ERPS primary ring is allowed to be created per domain.
Examples
This example shows how to create a sub ring with ID 1 for ERPS domain 11.
Switch# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#erps 11 ring 1 level sub
And you can check the result by using “show erps 11” command.
Switch# show erps 11
ERPS domain ID: 11
ERPS domain name: test11
ERPS domain primary control VLAN ID: 16
ERPS domain sub control VLAN ID: 15
ERPS domain hello timer interval: 1 second(s)
ERPS domain fail timer interval: 5 second(s)
ERPS ring ID: 1
ERPS ring level: sub
ERPS ring 1 node mode: unknown
ERPS ring 1 node state: idle
ERPS ring 1 primary interface name: not configured
ERPS ring 1 secondary interface name: not configured
Related Commands
None
8.5 erps ring mode
Use this command to set/unset specific ERPS ring instance node mode.
Command Syntax
erps ERPS_ID ring RING_ID mode {master | transit}
no erps ERPS_ID ring RING_ID mode
ERPS_ID : <1-255> ERPS domain ID
RING_ID : <1-255> ERPS ring ID
master: master node
transit: transit node
Command Mode
Global configuration
Usage