5 erps ring mode – CANOGA PERKINS CanogaOS Command Reference User Manual
Page 169

CanogaOS Command Line Reference
Revision 1.02
Proprietary & Confidential Canoga Pertkins Metro Ethernet Switches
Page 169 of 855
Only one ERPS primary ring is allowed to be created per domain.
 
Examples 
This example shows how to create a sub ring with ID 1 for ERPS domain 11. 
Switch# configure terminal 
Enter configuration commands, one per line. End with CNTL/Z. 
Switch(config)#erps 11 ring 1 level sub 
 
And you can check the result by using “show erps 11” command. 
Switch# show erps 11 
ERPS domain ID: 11 
ERPS domain name: test11 
ERPS domain primary control VLAN ID: 16 
ERPS domain sub control VLAN ID: 15 
ERPS domain hello timer interval: 1 second(s) 
ERPS domain fail timer interval: 5 second(s) 
ERPS ring ID: 1 
ERPS ring level: sub 
ERPS ring 1 node mode: unknown 
ERPS ring 1 node state: idle 
ERPS ring 1 primary interface name: not configured 
ERPS ring 1 secondary interface name: not configured 
 
Related Commands 
None
8.5 erps ring mode
Use this command to set/unset specific ERPS ring instance node mode.
 
Command Syntax 
erps ERPS_ID ring RING_ID mode {master | transit} 
no erps ERPS_ID ring RING_ID mode 
ERPS_ID : <1-255> ERPS domain ID 
RING_ID : <1-255> ERPS ring ID 
master: master node 
transit: transit node 
 
Command Mode 
Global configuration
 
Usage 
