45 sflow commands, 1 sflow enable, 2 sflow collector – CANOGA PERKINS CanogaOS Command Reference User Manual
Page 848

CanogaOS Command Line Reference
Revision 1.02
Proprietary & Confidential Canoga Pertkins Metro Ethernet Switches
Page 848 of 855
45 Sflow Commands
45.1 sflow enable
Use this command to enable or disable sFlow globally. 
 
Command Syntax
(no|)sflow enable
sflow: Sampled flow 
enable: Enable sFlow services 
Command Mode 
Global configuration mode 
Usage
Before any other sFlow command can be configured, sFlow services must be enabled globally. Use the no 
parameter with this command to remove all sFlow configurations and disable sFlow globally. 
 
Examples
This example shows how to enable sFlow services globally.
Switch# configure terminal 
Switch (config)# sflow enable 
 
Related Commands
45.2 sflow collector
Use this command to configure sFlow collector. 
 
Command Syntax
(no|)
sflow collector (<1-65535>|)
sflow: Sampled flow 
collector: Set sFlow collector 
A.B.C.D: Collector IP address 
<1-65535>: Collector UDP port number, default is 6343 
Command Mode
Global configuration mode 
 
Usage
Use this command to add a collector by specifying the combination of IP address and UDP port. Only up to