Lift up the bushing side of the pick roller slightly (about 5 mm), move it towards the
bushing, and pull it out.
ATTENTION
Be careful not to touch the gear near the bushing on the shaft because it has grease
over it.
d
Install the new pick roller in the scanner.
Replacing the Consumables