Show system pluggable detail, Figure 59. show system pluggable detail command – Allied Telesis AT-FS970M Series User Manual
Page 244

Chapter 10: Port Parameter Commands
244
SHOW SYSTEM PLUGGABLE DETAIL
Syntax
show system pluggable detail
Parameters
None
Mode
Privileged Exec mode
Description
Use this command to display information about the SFP modules in the
switch. See Figure 59. The SHOW SYSTEM PLUGGABLE DETAIL
command provides more detailed information than the SHOW SYSTEM
PLUGGABLE command. See “SHOW SYSTEM PLUGGABLE” on
page 243.
Figure 59. SHOW SYSTEM PLUGGABLE DETAIL Command
The OM1 field specifies the link length supported by the pluggable
transceiver using 62.5 micron multi-mode fiber. The OM2 field specifies
the link length supported by the pluggable transceiver using 50 micron
multi-mode fiber.
Example
This example displays detailed information about SFP modules:
awplus# show system pluggable detail
Port1.0.49
==========
Vendor Name:ATI
Device Name:AT-SPSX
Device Type:1000BASE-SX
Serial Number:A03240R084200741
Manufacturing Datecode:20081018
SFP Laser Wavelength:850nm
Link Length Supported
OM1 (62.5um) Fiber:270m
OM2 (50um) Fiber:550m