Circuit failover grouping, Circuit failover, Grouping – Brocade Network Advisor SAN User Manual v12.3.0 User Manual
Page 991: Considerations and limitations

Brocade Network Advisor SAN User Manual
939
53-1003154-01
FCIP trunking
22
The following actions occur during circuit failures:
•
If either circuit 0 or circuit 1 fails, traffic flows over the remaining circuit while the failed circuit
is being recovered. The available bandwidth is still considered to be 1.5 Gbps.
•
If both circuit 0 and circuit 1 fail, there is a failover to circuits 2 and 3, and the available
bandwidth is updated as 2 Gbps.
•
If a low metric circuit becomes available again, the high metric circuits return to standby
status, and the available bandwidth is updated again as each circuit comes online. For
example, if circuit 0 is recovered, the available bandwidth is updated as 1 Gbps. If circuit 1 is
also recovered, the available bandwidth is updated as 1.5 Gbps.
Circuit Failover Grouping
With Circuit Failover Grouping you can better control which metric 1 circuits will be activated if a
metric 0 circuit fails. For this feature, you define a set of metric 0 and metric 1 circuits that are part
of the same failover group. When all metric 0 circuits in the group fail, metric 1 circuits will take
over data transfer, even if there are metric 0 circuits still active in other failover groups.
Typically, you would only define one metric 0 circuit in the group so that a specific metric 1 circuit
will take over data transfer when the metric 0 fails. This will also avoid the problem of the tunnel
operating in a degraded mode with less than the defined circuits before multiple metric 0 circuits
fail.
Configure failover groups using the Add FCIP Circuit dialog box. Refer to
page 962 for instructions.
Considerations and limitations
Failover groups operate under the following conditions;
•
Each failover group is independent and operates autonomously.
•
All metric 0 circuits in a group must fail before the metric 1 circuits are used.
•
All metric 1 circuits in a group are used if all metric 0 circuits in the group fail or there is no
metric 0 circuit in the group.
•
Circuits can be part of only one failover group
•
Failover circuit groups are only supported at Fabric OS v7.2.0 or greater.
•
Both ends of the FCIP tunnel must have the same failover circuit groups defined for the feature
to function properly.
•
When a tunnel activates or circuits are modified, tunnel and circuit states will indicate a
misconfiguration error if failover circuit group configurations are not valid.
•
Modifying of the failover group ID is a disruptive operation, similar to modifying the metric.
•
Circuit failover groups are not used to define load balancing over metric 0 circuits, (ONLY
failover rules). Circuits of metric 0 will be load balanced over regardless of failover grouping.
•
When no FCIP circuit failover groups are defined, failover reverts to default operation - all
metric 0 circuits must fail before failing over to metric 1 circuit(s). In order to change default
failover operation, a failover group should include at least one metric 0 and at least metric 1
circuit.