Supported flow parameters, Number of supported flows – Brocade Network Advisor SAN User Manual v12.3.0 User Manual
Page 1183

Brocade Network Advisor SAN User Manual
1131
53-1003154-01
Flow Vision flows
29
•
Support for 16 Gbps F_Ports and F_Port trunks is provided on the following devices:
-
Switches: 24-port, 48-port, and 96-port 16 Gbps switches
-
Chassis: 4-slot and 8-slot 16 Gbps Backbone Chassis
-
Blades: FC8-32E, FC8-48E, FC16-32, FC16-48, and FC16-64
•
Disabling a SIM-port that is receiving traffic may produce Class 3 discards for the simulated
traffic; however, this will have no effect on other traffic flows.
Supported flow parameters
lists the supported flow configuration parameters for the Flow Vision Generator, Monitor,
and Mirror features.
Number of supported flows
On chassis-based platforms, Flow Vision supports a maximum of 512 user-defined flows. On
fixed-port platforms, Flow Vision supports a maximum of 128 user-defined flows. However, there is
a combined limit from all features of 64 flows (including static flows, root flows, and sub-flows,
whether active or inactive) for any one port. In addition, there are individual limits for each Flow
Vision feature;
lists these limits. When you create a flow, Flow Vision verifies that there is
no identical active flow.
Refer to the individual features for feature-specific restrictions.
TABLE 91
Supported flow parameters
Parameter
Flow Generator
Flow Monitor
Flow Mirror
Ingress switch port
Supported
Supported
Supported
Egress switch port
Supported
Supported
Supported
Source end device
Supported
Supported
Supported
Destination end device
Supported
Supported
Supported
Source FID/VFID
Supported
Supported
Supported
Destination FID/VFID
Supported
Supported
Supported
Bidirectional
Not applicable
Supported
Supported
Mirror port
Not applicable
Not applicable
Supported
LUN ID
Not applicable
Supported
Supported
Frame type
Not applicable
Supported
Supported
TABLE 92
Feature-specific flow count restrictions in Flow Vision
Feature
Limit to number of flows
Flow Monitor
Up to 64 active flows per port, including static flows, root flows, and sub-flows.
Flow Generator
Up to 4 active flows per port, including static flows, root flows, and sub-flows.
Flow Mirror
One active flow per switch.