Brocade Network Advisor SAN User Manual v12.3.0 User Manual
Page 596

544
Brocade Network Advisor SAN User Manual
53-1003154-01
Administrative Domain-enabled fabric support
12
•
If you try to enable Virtual Fabrics on an AD-enabled switch, that operation fails with the
following message: “Failed to enable Virtual Fabric feature for Chassis (Remove All ADs before
attempting to enable VF).”
•
Performs performance management (including Advance Performance Monitoring and Top
Talkers) data collection and reports in a physical fabric context.
•
If AD is enabled any switch in a fabric, you cannot clear counters (performance management)
on any switch in that fabric.
Management application support for AD-enabled fabrics
details feature support for AD-enabled fabrics in the Management application.
TABLE 53
Feature support for AD-enabled fabrics
Feature
AD context
ADO AD255 Not supported All AD
User interface impact
Allow/Prohibit Matrix
X
Filters AD-enabled fabric
from the Fabrics list.
Cascaded FICON/FICON Merge
X
Filters AD-enabled fabric
from the Fabrics list.
Configuration Management
X
None.
Configuration Management >
CEE
FCoE
Swap Blades
X
Filters AD-enabled fabric
from the product tree.
Encryption
X
Filters AD-enabled fabric
from the dialog box.
Fabric Binding
X
Filters AD-enabled fabrics
from the Fabrics table.
Displays all switches
(including switches in an
AD-enabled fabric) in the
Available Switches table.
Fabric discovery (except zoning)
X
None.
Fault Management
Displays all events from
the switch in the Master
Log regardless of AD
membership.
None.
FCIP Tunnels Configuration
X
Filters switches from an
AD-enabled fabric from
the dialog box.
Firmware Management
X
None.
High Integrity Fabric (HIF)
X
Filters AD-enabled fabric
from the Fabrics list.
Logical Switches
X
None.
Names configuration
X
None.
Performance Management
X