Brocade Network Advisor SAN User Manual v12.3.0 User Manual
Page 1462

1410
Brocade Network Advisor SAN User Manual
53-1003154-01
Host adapter reports
35
Encoding
Displays how the extended link is encoded, for example, 8B10B.
Baud Rate
The transmission rate, roughly equivalent to the number of bits per second.
Length 9U1
The length of the single-mode fiber-optic cable, used in situations where gigabit
performance is not required (for distances greater than 100 meters).
Length 9U2
The length of the single-mode fiber-optic cable, used in situations where gigabit
performance is not required (for distances greater than 100 meters).
Length 50u
The length of the 50u fiber-optic cable (for distances greater than 10 meters).
Length 62.5u
The length of the 62.5u fiber-optic cable (for distances greater than 10 meters).
Length Cu
The length of the copper cable (for distances greater than 1 meter, where optimum
performance is required).
Vendor Name
The vendor of the extended link.
Vendor OUI
The vendor’s organizational unique identifier (OUI).
Vendor Part
The part number of the extended link.
Revision
The revision level of the extended link.
Wavelength
The wavelength translation, which enables longer reach through lower attenuation.
Options
Displays details about the transceiver; for example, the type of port connector, type of
transceiver, and enable/disable status.
BR Max
The upper bit rate limit at which the SFP transceiver meets its specifications.
BR Min
The lower bit rate limit at which the SFP transceiver meets it specifications.
Serial #
The serial number of the SFP transceiver.
Date Code
The date the SFP was manufactured transceiver.
Temperature (c)
The port temperature, measured in Celsius.
Bias Current (mA)
The low-level DC current (the Bias Current), measured in mA.
Tx Power (mW)
The transmitted power, measured in mW.
Rx Power (mW)
The received power, measured in mW.
Voltage (V)
The voltage; for example, 1.8V, 3.3V, or 5.0V.
Alarm/Warning
Indicates whether an alarm has been triggered.
TABLE 126
Adapters Faulty SFP report fields and components (Continued)
Field/Component
Description