Flow definitions, Flow definition parameters and rules, Supported frame type parameters – Brocade Network Advisor SAN User Manual v12.3.0 User Manual
Page 1181: Flow frame type parameters

Brocade Network Advisor SAN User Manual
1129
53-1003154-01
Flow Vision flows
29
Flow definitions
To define a flow and configure Flow Vision to monitor that flow, you must provide a unique flow
name and specify the flow parameters. These parameters identify the sets of related frames and
can either be explicitly defined or Flow Vision can learn them through observation.
Flow definitions are stored on the switch on which you create the flow, and are not distributed
across the fabric. This means that each switch knows only its own flows and does not know what
flows exist on other switches.
You can create three types of flows: Monitor, Generator, and Mirror. For specific procedures for
defining flows, refer to the following topics:
•
“Creating a Flow Monitor flow definition”
•
“Creating a Flow Generator flow definition”
•
“Creating a Flow Mirror flow definition”
Flow definition parameters and rules
identify the parameters that can be used to define a flow.
Flow frame type parameters
Frame monitoring can be performed for a variety of frames using predefined frame type
parameters. To access the Frame Type Picker dialog box, click the ellipsis button next to the Frame
Type field on the Add Flow Definition dialog box.
lists the frame type parameters and the frames counted for each.
TABLE 88
Flow definition rules
Parameters
Field names
Rules
Port
Ingress
Egress
•
Only one field must be specified
•
Values must be explicit
Frame
Source
Destination
LUN
Frame Type
1
1.
for more information on frame types.
•
At least one field must be specified
•
Values for source and destination can be explicit or “*” (“*” indicates a
learned flow)
•
Values for LUN and frame type must be explicit
TABLE 89
Supported frame type parameters
Frame type parameter Frames counted
abts
Abort sequence frames
baacc
All frames accepted
barjt
All frames rejected
scsi
All SCSI frames (including both command and data frames)
scsiread
Only SCSI read command frames
scsiwrite
Only SCSI write command frames
scsirw
Both SCSI read and write command frames