External radius server settings – Brocade Mobility RFS7000-GR Controller System Reference Guide (Supporting software release 4.1.0.0-040GR and later) User Manual
Page 480

466
Brocade Mobility RFS7000-GR Controller System Reference Guide
53-1001944-01
Configuring management users
7
7. Click Cancel to revert back to the last saved configuration without saving any of your changes.
External RADIUS Server settings
When using an external RADIUS Server with the switch, ensure that the following values are
configured on your server to ensure maximum compatability with the switch.
Vendor ID
RADIUS VSAs
There are two RADIUS VSAs used for management user authentication.
Vendor ID
The Brocade vendor ID is 1991
VSA Name
Attribute Number
Type
Values
Symbol-Service-Type
1
Integer (Decimal)
•
Monitor Role: Value is 1.
(read-only access to the switch)
•
Helpdesk Role: Value is 2
(helpdesk/support access to the
switch)
•
Nwadmin Role: Value is 4
(all wired and wireless access to the
switch)
•
Sysadmin Role: Value is 8.
(System administrator access)
•
WebAdmin Role: Value is 16
(Guest user application access)
•
Superuser Role: Value is 32768
(grants full read/write access to the
switch)
To configure multiple roles this value may
configured multiple times with different
values for each role.
Symbol-Login-Service
100
Integer (Decimal)
•
Console Access: Value is 128
(user is allowed to login only from
console)
•
Telnet Access: Value is 64
(use is allowed to login only from
telnet session)
•
SSH Access: Value is 32
(user is allowed to login only from
ssh session )
•
Web Access: Value is 16
(user is allowed to login only from
web/applet)
To configure multiple access methods this
value can be set multiple times with
different access values, or the desired
values can be added together and and
entered as a single value.