Brocade Mobility RFS7000-GR Controller System Reference Guide

301

53-1001944-01

Locationing

5

3. Click the Add button..

Configuring SOLE parameters

To configure the switch’s internal SOLE locationing engine:

1. .Services > RTLS from the main menu tree.

2. Select the SOLE tab.

3. Check the Locate All Mobile-Units checkbox to locate all MUs known to the switch across all

WLANs. This will also disable manual entry of MU MAC addresses in the field below.
This takes effect immediately when the box is checked.

4. Enter a value for the MU Locate Interval in seconds. The MU Locate Interval determines how

often the locationing of MUs is updated. The valid range for this is between 5 to 3600 seconds.