beautypg.com

Meridian America Link/Customer Controlled Routing User Manual

Page 489

background image

Chapter 14: Software installation, upgrade, and update procedures 471

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Procedure 9: Restore configuration files and data files from
the backup tape

1

At the ÒConsole Login:Ó prompt, type maint and press [Return].

2

You are prompted for a password. Type the password and press
[Return]. The default password is maint.

3

At the Òmaint>Ó prompt, type rstdata and press [Return].

Prompts similar to the following appear:

Figure 250
Rstdata prompt

Make sure tape is in drive
When ready, enter ÔyÕ to continue, or ÔnÕ to quit: [y,n]

4

You are prompted to prepare the tape drive. Insert the most recent
backup tape for your application data.

Note: Wait until the tape indicator light turns off before proceeding to
the next step.

5

When the tape is ready, type y and press [Return].

Figure 251
Stop applications prompt

The restore will not succeed with an application running.
Enter ÔyÕ to stop the application(s) and continue, or ÔnÕ to quit: [y,n]

6

If an application is not running, go to step 7. If an application is
running, you will be prompted to stop all applications. Type y and
press [Return].